SPECIFICATION (PRELIMINARY)
| GENERAL DATA |
Mobile equipment |
|
Supply voltage
|
220 V +/- 10 %, 50 Hz
|
|
Supply fuse
|
6 A
|
|
Ambient temp.
|
0 to +40 degrees Celsius
|
|
Electronic cabinet (one channel)
|
600 x 600 x 350 (w x h x d)
|
|
Case size
|
19"
|
|
Degree of protection
|
IP 44
|
|
Components
|
Common industrial types (no special)
|
|
PERFORMANCE AND RELATIONSHIPS*
|
|
Minimum detectable crack depth
|
DJspr: GK / 50 mm
|
|
Minimum detectable crack length
|
Lspr: GK / 1,5 mm (100% surface scanning)
|
|
Minimum detectable surface hole diam
|
Dh: GK / 12 mm (hole depth = GK / 1)
|
|
Minimum detectable sliver (flake) depth
|
DJsl: < GK / 80 mm
|
|
Maximum allowed surface structure
|
PFp-p: GK / 40 mm (sinusoidal function)
|
|
Maximum allowed lift-off (free air)
|
LO: GK / 2 mm
|
|
Current penetration depth (approx)
|
DIH: GK / 25 mm (for max carrier frequency)
|
|
Carrier frequency
|
RF: f(DIH) **
|
* Expected result and limitations for DELTATEST
can easily and approximately be calculated
by a sensor constant named GK, with a signal/nois ratio, S/ N > 3.
GK is a unlinear function of sensor dimensions.
GK = 0,5 to 50
First step : Choose suitable value (0,5 - 50) for GK, and then, calculate current function.
**
|
MEASURING UNIT |
Standard performance (One channel)
|
|
Number of units
|
One unit per channel/sensorcoil
|
|
Dimension, racket
|
19" (w) x 133 mm (h) x 250 mm (d)
|
|
Printed circuits board (PCB)
|
14 pieces, single europe card (100 x 160 mm)
|
|
Basic measuring Principles
|
Frequency conversion, Vectortransformation
|
|
Frequency generation
|
Crystal-controlled digital frequency synthesizer
|
|
Carrier / Operating frequencies, RF
|
1 - 64 MHZ (function of DIH)
|
|
Conversion
|
Single (other on request)
|
|
Intermediate frequency, IF
|
62,5 - 500 KHZ (standard IF = 250 KHZ)
|
|
Signal execution time / crack, Tc
|
< 2ms (unit ready to serve next crack)
|
|
Reset after Tc
|
Automatic, high speed
|
|
Input impedance, Zin
|
50 ohm
|
|
Common-mode rejection
|
On request (very high)
|
|
Mixer
|
Doubly balanced modulator
|
|
Synchronous detectors
|
Doubly balanced demodulator
|
|
Selectivity
|
On request (> 10 times better than conventional systems)
|
|
Sensitivity
|
Please, see at performance
|
|
Phase setting
|
Switches on PCB or panel
|
|
Sensitivity setting
|
Potentiometers on panel
|
|
Vector setting
|
Potentiometers on PCB or panel
|
|
Balancing (BAL)
|
Automatic
|
|
Blocking (BL)
|
Blocking function
|
|
Digital input signal, BAL
|
BAL, active
|
|
Digital input signal, BL
|
BL, active
|
|
Digital output signal DFP
|
Delayed crack signal or relay contact (10 ms - 1 s)
|
|
Analogous output signal, CS
|
Crack Signal
|
|
Alarm
|
LED indicator for unbalans alarm
|
|
OPTIONAL SIGNALS
|
Separate cabinet
|
|
Digital output signal, SB
|
Strobe / order signal (CBC)
|
|
Digital output signals, CBC
|
Crack depth Binary Code (4 to 6 bit)
|
|
Digital output signal, CO
|
Crack Overflow
|
|
Digital input signal, RC
|
Receipt, Crack registration
|
|
ROTATING SENSOR
|
Standard performance incl preamplifier
|
|
Detected defects
|
Surface- cracks, holes, slivers etc
|
|
Detected cracks
|
Longitudinal and transversal
|
|
Allowed crack orientation
|
All (no restrictions)
|
|
Surface scanning pattern
|
On request
|
|
Allowed lift-off
|
GK / 2 (Please see PERFORMANCE)
|
|
Preamplifier
|
Balanced
|
|
Preamplifier output impedance Zout
|
50 ohm
|
|
Signal transmission
|
Inductive (no galvanic contact)
|
|
Energy transmission
|
Inductive (no galvanic contact)
|
|
Crackdepht indicator
|
LED scale, 10 piece
|
|
Connectors
|
BNC
|
|
Cable type
|
Coax, RG 58
|
|
Cable length, sensor - measuring unite
|
4 m (other on request)
|
|
OPTIONAL PERFORMANCE
|
|
|
Frequency Difference Measuring
|
FD
|
|
Phase Discrimination, Product-Quotient
|
PD-PQ
|
|
Phase Discrimination, Phase-Expansion
|
PD-PE
|
|
Dynamic Transformation
|
DT
|
|
Lift-Off-Compensation
|
LOC
|
|
Queue Function
|
QF
|
Please, see SENSORS for more information.
Expected performance, Examples
Download as World-document (ca 31K)
|